California Cancer Reporting System Standards, Volume III

IF769: CS Eval Items, Type of Reporting Source (CS)

Edit Sets

California Hospital Transmit

Eureka Admission Level

Eureka Tumor Level

Fields

Type of Reporting Source  [NAACCR #500]

Behavior Code ICD-O-3  [NAACCR #523]

CS Tumor Size Ext Eval  [NAACCR #2820]

CS Lymph Nodes Eval  [NAACCR #2840]

CS Mets Eval  [NAACCR #2860]

Primary Site  [NAACCR #400]

Histologic Type ICD-O-3  [NAACCR #522]

CS Site-Specific Factor 25  [NAACCR #2879]

Message

IF 769:  Conflict among CS Eval fields and Type of Reporting Source

Specification

This edit is skipped if any of the following conditions are true:

If CS Tumor Size/Ext Eval, CS Lymph Nodes Eval, or CS Mets Eval = 8 (evidence from autopsy only (tumor was unsuspected or undiagnosed prior to autopsy)), then Type of Reporting Source must = 6 (autopsy only).

historical changes

In the SEER* Edits software, the title of this edit is: IF193.

02/20/08

Added new edit from NAACCR 11.2 file effective with 2008 diagnosis year cases.

2010

Data Item Changes: CCR names (CS TS Ext Eval; CS Reg LN Eval; Report Source) changed to NAACCR names.

04/2014

Function call to the CS Dynamic Link Library updated to call "CStage0205.dll" instead of "CStage.dll."